Roof drains and storm drainage piping are sized based on which two factors?
Not quite. The answer is A: Roof area (or projected horizontal area) and the local rainfall rate for the design storm
Storm drainage is a hydrology calculation, not a fixture-count calculation: leaders and drains are sized from the maximum projected roof area and the rainfall rate for the design storm (the UPC bases primary drainage on a 60-minute, 100-year storm unless the authority having jurisdiction says otherwise). DFU-based sanitary sizing measures a completely different quantity.
Checked against the 2021 UPC text. Washington's exam is written against the 2015 edition, which we have not read for this section, so confirm it against your 2015 book.
More Washington Journeyman Plumber practice questions
Trade Code Wizard is not affiliated with, endorsed by, or licensed by the International Code Council (ICC), the National Fire Protection Association (NFPA), IAPMO, the ESCO Institute, NATE, HVAC Excellence, NASCLA, NICET, the U.S. Environmental Protection Agency, PSI, Prov, Pearson VUE, or any state or local licensing board. Exam and code names are used only to identify which examination this study material prepares you for.
These are original practice questions written to publicly published exam content outlines. They are not actual exam questions, and they do not reproduce code text. Explanations cite code sections and state requirements in our own words — always verify against the code edition your jurisdiction has adopted, which may differ from the edition cited here.