A bathroom group under the UPC consists of 1 water closet (1.6 gpf gravity tank, private), 1 lavatory (private), and 1 bathtub. What is the total DFU load, using UPC fixture-unit values?
Not quite. The answer is B: 6
Add the three table values: the private water closet is 3 DFU, the lavatory 1 DFU and the bathtub 2 DFU, for 6 DFU. The trap is treating the group as one lump value or mixing in the public-use column; on the exam you add each fixture from Table 702.1.
Reference: UPC 2021 Table 702.1 (Drainage Fixture Unit Values)
Checked against the official text
The exam supplies this table at the desk, so the edition it prints is the one that counts on test day.
Trade Code Wizard is not affiliated with, endorsed by, or licensed by the International Code Council (ICC), the National Fire Protection Association (NFPA), IAPMO, the ESCO Institute, NATE, HVAC Excellence, NASCLA, NICET, the U.S. Environmental Protection Agency, PSI, Prov, Pearson VUE, or any state or local licensing board. Exam and code names are used only to identify which examination this study material prepares you for.
These are original practice questions written to publicly published exam content outlines. They are not actual exam questions, and they do not reproduce code text. Explanations cite code sections and state requirements in our own words — always verify against the code edition your jurisdiction has adopted, which may differ from the edition cited here.