A gas water heater sits in a small, sealed closet with no dedicated combustion-air openings. What is the most likely violation?
Not quite. The answer is B: Insufficient combustion air supply to the appliance
A sealed closet starves a gas appliance of the air it needs to burn fuel completely and vent safely, risking carbon monoxide in the space — a life-safety problem unrelated to drain proximity, relief-valve materials, or expansion control. In Washington the combustion-air rules for fuel-burning water heaters come from the Mechanical Code, not the UPC's own chapter 5.
Reference: WAC 2021 51-56-0500, §506.0 (Combustion air for water heaters is governed by the Mechanical Code in Washington)
Checked against the official text
More Washington Journeyman Plumber practice questions
Trade Code Wizard is not affiliated with, endorsed by, or licensed by the International Code Council (ICC), the National Fire Protection Association (NFPA), IAPMO, the ESCO Institute, NATE, HVAC Excellence, NASCLA, NICET, the U.S. Environmental Protection Agency, PSI, Prov, Pearson VUE, or any state or local licensing board. Exam and code names are used only to identify which examination this study material prepares you for.
These are original practice questions written to publicly published exam content outlines. They are not actual exam questions, and they do not reproduce code text. Explanations cite code sections and state requirements in our own words — always verify against the code edition your jurisdiction has adopted, which may differ from the edition cited here.