True or False: Under Washington's seismic provisions, a water heater must be braced, anchored, or strapped to resist horizontal displacement, typically restrained at points in both the upper and lower one-third of the tank.
Not quite. The answer is A: True
Washington's text requires a water heater to be anchored or strapped against horizontal movement from earthquake motion, with straps within the upper one-third and the lower one-third of the tank's height — and the lower strap kept at least 4 inches from the controls. Two restraint points keep the tank from tipping or walking, which is why a single top strap isn't adequate: it leaves the base free to swing out.
Reference: WAC 2021 51-56-0500, §507.2 (Water heater seismic restraint)
Checked against the official text
Trade Code Wizard is not affiliated with, endorsed by, or licensed by the International Code Council (ICC), the National Fire Protection Association (NFPA), IAPMO, the ESCO Institute, NATE, HVAC Excellence, NASCLA, NICET, the U.S. Environmental Protection Agency, PSI, Prov, Pearson VUE, or any state or local licensing board. Exam and code names are used only to identify which examination this study material prepares you for.
These are original practice questions written to publicly published exam content outlines. They are not actual exam questions, and they do not reproduce code text. Explanations cite code sections and state requirements in our own words — always verify against the code edition your jurisdiction has adopted, which may differ from the edition cited here.