True or False: A grease interceptor's inlet and outlet connections follow the same vent-distance principles as any other trapped fixture connection.
Not quite. The answer is A: True
An interceptor's larger size doesn't exempt it from ordinary trap-seal physics — its inlet and outlet are still vulnerable to siphoning if run an excessive distance without a vent, so the same distance-based venting logic that applies to a sink trap applies here too.
Reference: UPC 2021 §1014.1.1 (Fixtures discharging to an interceptor must be trapped and vented)
Checked against the official text
Checked against the 2021 UPC text. Washington's exam is written against the 2015 edition, which we have not read for this section, so confirm it against your 2015 book.
Trade Code Wizard is not affiliated with, endorsed by, or licensed by the International Code Council (ICC), the National Fire Protection Association (NFPA), IAPMO, the ESCO Institute, NATE, HVAC Excellence, NASCLA, NICET, the U.S. Environmental Protection Agency, PSI, Prov, Pearson VUE, or any state or local licensing board. Exam and code names are used only to identify which examination this study material prepares you for.
These are original practice questions written to publicly published exam content outlines. They are not actual exam questions, and they do not reproduce code text. Explanations cite code sections and state requirements in our own words — always verify against the code edition your jurisdiction has adopted, which may differ from the edition cited here.